The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. my hayward filter assembly on top leaks at the seam between the top (held on by six bolts) and the bottom. Hi Davy! The cord does feel warm to the touch. Is that a reason to replace impeller? Be sure that all pool valves are open and any wall plugs are removed before turning on pump. However this is not correct operation. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. They do not seem to have enough stooch even though they are rated at 1HP like my original motor. If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. If so, put a damper under the pump, a piece of heavy rubber or a shim to stabilize the pump. Examine your pumps impeller for any obstructions, and replace the capacitor if necessary. Hi Davy, One washer on each side of the spring, you are correct. After 15-20 minutes, after cooling, the switch will close again, and the motor should restart. On a DE filter, water enters the tank through the bottom tank bulkhead, and is when the tank fills up, water is forced through the grids, and then up thru the manifold, and down the standpipe to the top exit bulkhead DE inside the grids, must have been missing an o-ring before, a push-pull valve plunger ring? Pool is ALMOST perfectly clear, BUT, for the life of me, I cannot get pressure to stay strong when vacuuming. If it does, check power inside of the back of the motor, with a test meter. It wont respond to the controls at all. Corrosion inside the plug or socket. Wire size inside socket too small (cant carry the current). On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. Thanks A. Ray Davis The price seems steep ($500+ for the pump) and it seems only Leslies carries them. When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. No need to look for a solution after the impeller, its always before, on the suction side. Typically, the LED light should shut off after 60 seconds. Profile, Create a Pool Professional Fourth possibility is that the other lines (skimmer or main drain) are partially clogged or valves closed, not allowing enough water to enter pump, while vacuuming. Hi Mark, there are salt and ozone resistant shaft seals that can be used, the salt could be the problem, or it could be caused by a water-hammer effect, where flowing water is shut-ff suddenly by a closed valve on the return side, or turning a filter valve while the pump is running. A common mistake is to install the spring seal half backwards. Does it sound like the capacitor or could something else be the culprit? 2017). If so, it will always read 100%. If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. Then check the GFCI for loose wires. I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. Cheers! I have replaced my existing super pump with new one. Are you getting 230V (207v 253V) at the pump? Product Type Model Name Select Model # Id call the install tech for troubleshooting. But not a dirty filter? Hi, it is either an air leak (a non-issue if installed below water level), or the suction pipes are too small for the pump size, or the hose may be collapsing inward under pressure. Any idea how to fix this? They dont typically make noise for long either, because at 3400 RPM, if the impeller is hitting something, it will quickly wear it down. Then sometimes with no rhyme or reason the pump shuts down and will not come back on until after I turn off and on all breakers. If valve is open when it should be closed the heater will shut down and go into lockout. Well call it assy B. Assy B has a bad on/off switch that sparks when you try to dislodge it from its position, but DOES start and run, until I unplug it. High will run fine but next day I have to do the same, start with low and switch to high. Recently when power came on it hums and shuts down after 6 seconds. Mine hums and then trips the breaker. We only use the pump in the summer months, since we live in Canada. Only thing I can think of, is the Key assy aligned properly when it was screwed back onto the valve body? What does F5 mean? It works fine otherwise, but the only way to stop it from heating up to 104 is by turning the power off to the heater. Is it a defective motor or something else? Hi Tracy, the C48 number is not the pump model, but the motor number. Hi Deb, probably a bad outlet or a bad cord, or a loose connection on one or both of those. If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. What do I need to do to fix this? However, I havent tried to spin the shaft. My mistake was forgetting to empty pump basket. it runs My salt was tested today at 3000 and everything else was perfect. Good morning. If the wiring is Ok and the error persists, replace the sensor. Thanks. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Long story short, bought a house that had an above ground pool that would not get the pool clear. This occurred after a lengthy power outage. You can patch the fitting usually with pool putty or silicone, but the best repair is to replace the fitting. The best way to attack this is with the mantra the problem lies where the power dies. I checked the 20A fuse and it is good. I let it cooled down tho the temp was only 90 at that time. Thanks! I took out the filter cartridge and hosed it down replaced, emptied all the baskets but still no change, only one of the jets is pushing out water, but barely. Any insight? well, possibly it just needs to dry out. Power on LED is intermittently on or off. regardless, i am replacing the electrical cord. Some controllers have a Service Mode button you push, to be able to turn off equipment at the equipment pad, as opposed to an in-house remote panel. Do I need to do something else to get it to prime faster? Could also be that your vacuum hose has a big split in it if this only happens during vacuuming. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. It could also be a clogged impeller or clogged filter, or clogged skimmer line. If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. If the next day the chlorine level is nearly zero, shock again. It leaks from the impeler case and is noisey, so assy B is no replacement. Dear Davy, my pump was working two days ago then I switched it off. If yes, the motor bearings are the problem. "height": "219",
Click here to shop our store. And you cant rule out a problem with the circuit board either. Hello, Just bought a house with a pool in January. Our unit comes on for about 15 secs. Thank you. Hi Dave..your honest opinion please..new 14000gal gunite pool with hayward sp3400vsp pump September 2014,ran a month winterized and ran fine for 3 years, when company came to open up the pool in 2017,pump stuck,installed new 3400@ $1200. "@type": "BlogPosting",
If needed, you could replace just the motor, and the shaft seal, and save a few hundred bucks. To keep the water clear, hand feed liquid or granular chlorine daily, and brush/skim the pool daily. Should I have it checked or is this normal? Hi Nancy, Heat Sinks are designed to absorb the heat from the motor, and dissipate it safely. Lube Gasket (after cleaning, with a rag lube with Teflon or Silicone based pool lube) and 3. I was just wondering if you thought that could be the issue unless it could be something else. Finally, could be that the voltage is not quite right, one of the legs (power wires) not providing enough power. Look on the cap for the MFD number and replace with exact duplicate. The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Turned everything off, let the motor cool off and tried again. If the shaft is free turning, but the pump does not turn on, check power connections. We believe it needs a new seal. I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. If thats all ok, you may want to shut off the isolation vales, and remove the handle and lid from the multiport valve and inspect the spider gasket. "publisher": {
I just went out there to crank them up, after 10 minutes they shut off. Have a Hayward pump. YOu can shim under a piece of rubber, or carpet, or cardboard which wont last long, but anything between the pump and the pad should quiet the pump, and take up space to prevent the vibration. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing Following this procedure will identify News Reporter Reveals On Live TV That Shes Been Secretly Recording We would like to show you a description here but the site wont allow us. When I turn the switch on for the pool, the breaker flips immediately. The filter is clean. hayward blue essence troubleshootingsolar panel for arlo essential spotlight camera hayward blue essence troubleshooting Menu everydrop water filter comparison. Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. Troubleshooting a Salt Chlorinator First, check power. I opened the control panel during a rain storm (down pour) to turn off the filter. I will be replacing it tomorrow along with the electric socket. Air leaks are from a loose pump lid or dry pump lid o-ring, or from a loose pipe coming into the pump, or from leaky suction-side valves (SK/MD). If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. Motors have a thermal overload switch (in the rear of the motor, top-dead-center, at 12:00). Is the pump pot filling full of water, or does it ever catch prime fully? Remove the pump and basket, then look for and remove any debris in the shaft. I have a t-15 cell. "name": "In The Swim",
Although in low speed, chlorine is not generated so not sure why even run the low speed. I reset everything when I noticed the problem. I have a pump that wants to stop pumping water after a few minutes the flow gets very low. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. Help. There is another switch located at 6 oclock called the stationary switch. replacement. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. What is the problem with those other motors? Check that hoses are clamped tight to fitting. This is actually the second motor in 6 months. The motor model # is C48L2N134B1. Many two speed split capacitor motors use the capacitor to boost it to high speed, check the capacitor for bulging, splits, leaking or loose wires, or test for capacitance, or test with new one. I have a Hayward super pump every once in awhile when I go to unplug to backwash it sparks and trips the breaker. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About.